Pool Gas Heater Installation Tips (2023)

Pool Gas Heater Installation Tips (1)

A well-done heater installation ensures years of trouble-free satisfaction for customers and techs. But installed incorrectly, a heater can become a service nightmare, subject to a variety of operational problems. More importantly, these heaters pose a risk to customers and techs that must be dealt with — even if the techs had nothing to do with the installation. If you service a pool with an improperly installed heater and an injury occurs, you could be held liable whether you had anything to do with the accident or not. If you see installation-related problems, you must notify your client of the situation, preferably in writing. This will help you stay off the liability hook.
To do so, you must know what to look for when evaluating an installation. Although most requirements tend to be consistent among suppliers, you must always closely follow each manufacturer’s own installation guidelines at the job site.

Keeping your distance

The first step in a good installation concerns the heater’s placement relative to its surroundings — specifically, its clearances.

The American National Standards Institute helps out here by offering guidelines (ANSI Standard 2223.1), designed to keep heaters, whether installed indoors or out, at a safe distance from all combustible materials contained in nearby walls, landscaping or structures. (Because this standard sets clearance requirements based on the external temperatures of heaters, clearances may vary.)

• The rear and nonplumbed sides of the heater need at least 6 inches of clearance.• The water-connection side should have a minimum of 12 inches of clearance — 18 inches is recommended.
• The front of the heater should have at least 24 inches of clearance.

Moreover, the following clearances are based on the National Fuel Gas Code and are universal for all gas-heater models:

• When installing a heater under an overhang, there must be at least 4 feet of vertical clearance from the top of the heater to the overhang, and the heater must be open on three sides.• The top of the heater must be at least 5 feet below, or offset 4 feet from, the nearest opening to a building, such as a window or door; in addition, the top of the heater must be at least 3 feet above any forced-air inlets located within 10 feet of the unit.

All heaters must be installed at least 5 feet from the inside wall of a spa unless it is separated from the spa by a fence, wall or other permanent barrier.

(Video) Universal H Series & ASME Gas Heater Installation, Start-up and Troubleshooting

A secure heating pad

The heater must be installed on a level, noncombustible base such as brick or concrete. If a new pad must be built, there should be a minimum of 1 foot of clearance on the pad for all sides of the heater.
If concrete cinder block is used as a base, it must be aligned so the cells all point the same way; the end should be left open. When hollow masonry is used, the pad must be at least 4 inches high — and covered with a 24-gauge (or heavier) piece of sheet metal. Another option: Check with your distributor for a synthetic, lightweight, noncombustible pad to set the heater on.

Next, consider the elements. If the heater is placed in an area exposed to high winds, the unit either must be installed at least 3 feet from the nearest wall, or a wind block must be constructed to help minimize the effect of wind reflecting into the heater. (Most manufacturers provide recommended wind levels at which a device known as a vent cap also is required. Some manufacturers now also equip their heaters with low-profile vent assemblies.) Without proper air flow around the heater, efficient combustion is impossible and burnt fossil fuel cannot be safely vented. While this is an obvious concern outdoors, indoor installations are even more sensitive to such considerations — particularly with respect to venting.

Inside installations

The ground rules for heaters with sealed combustion chambers installed indoors are straightforward and rigid:

• If the heater is installed in a place where vented air comes from another interior room, the space where the heater is located must be connected to the additional airspace by two vents, and the combined area of the space where the heater is located and that additional room must represent at least 50 cubic feet per 1,000 BTUs of heater input. (The BTU input of any other gas-burning appliances in that space, such as a home water heater, also must be factored into this calculation.)

• The space must have two openings, one beginning 12 inches above the floor, the other 12 inches from the ceiling, per the code. The top opening is for replacement air (ventilation), while the bottom is for combustion air (what the heater uses).

• Each heater model has specific venting requirements to ensure proper combustion and prevent sooting. Manufacturers express venting requirements as square inches of net free air. A typical requirement is 1 square inch per 1,000 BTUs of input for an unobstructed opening. When venting heaters, don’t guess. Always consult the manufacturer or read the manual for venting sizing requirements for the specific model being used.

• For spaces vented to the outside, the space also must have top and bottom vents for the confined space. The openings must connect directly or be connected by ducts to the outdoors. Alternatively, the vents must connect to an area such as an attic or crawl space connected directly to the outdoors.

• Regardless of where the unit gets its air, indoor heater installations require a draft hood that sends combustion byproducts — particularly carbon monoxide — outside the building. Failure to meet this requirement can result in fire or carbon monoxide poisoning. (Some models have a built-in draft hood design that does not require an additional draft hood externally.)

(Video) NATURAL GAS INSTALLED FOR SWIMMING POOL HEATER

The diameter of the draft hood is based on the National Fuel Gas Code and may vary from model to model. Connected to the draft hood is the vent pipe, which vents products of combustion to the outside air; it must have a diameter equal to, or greater than, the draft hood.

While blower heaters don’t require as much room, the discharge opening in the vent pipe for other heater models must be at least 2 feet above the roof surface and at least 2 feet above the highest point on the roof within a l0-foot radius of the pipe location. Because the vent pipe is exposed to the elements, it also must be topped with an approved vent cap, which keeps wind and air from forcing products of combustion back down into the ventilation system.

In reaching this safe venting point, installers are urged by manufacturers to avoid horizontal piping runs if possible. If horizontal runs are inevitable, the vent pipe must have a minimum 1-inch rise for every foot of horizontal run and be supported at least every 5 feet. Go soft on angles, too, say manufacturers: 90-degree elbow connections should be kept to a minimum. Finally, there must be a piping clearance of at least 4 feet from all electric and gas meters.

Under pressure

Once venting needs are accommodated, consider whether the unit is getting an adequate supply of fuel. To answer this question, look at the line running from the gas meter to the heater and determine whether it is properly sized for the job.

Gas pressure is measured in inches of water-column pressure, or WCP, a special measure of pressure per square inch. It takes 28 inches of WCP to equal 1 psi. Generally, heaters running on natural gas require between 4 and 10 inches of WCP while the heater is operating to ensure smooth performance. Heaters on liquid petroleum require greater delivery pressures.

Manufacturers offer handy pipe-sizing charts for their customers, concentrating on sizes from 3/4- to 2-inch diameters and working with runs of up to 300 feet. (For longer runs, contact the manufacturer.) One more factor: Most heaters are fitted for operation at altitudes of less than 2,000 feet above sea level. For guidance on installations at higher elevations, contact the maker for special high-altitude models.

Next on the fuel list, determine the basic installation requirements for the gas connection, namely:

• A main gas-shutoff valve and union must be installed within 6 feet of the heater and outside the heater jacket.• Gas piping should have a sediment trap upstream of the heater’s gas controls.
• Rigid gas-line piping must be used. (Never should flex line be used.)

(Video) Hayward Universal H-Series Pool Heater Installation - AmeriMerc.com

Once the piping is installed, the system must be pressure-tested to ensure integrity. In testing, gas piping is disconnected from the heater to avoid damaging the heater’s gas-control equipment. Here, the pipe is capped at the connection point and pressure is applied, with a soap solution applied at all joints. (Never test for a gas leak with a match or any flame. Also, some local codes may have even more testing requirements.)

If bubbles form when the soap solution is applied, there’s a leak that needs repair. Testing continues until there are no leaks.

Some manufacturers suggest the above procedure to test the burner and pilot’s tubing. Here, care must be taken to keep the test pressure below 10 inches of WCP to avoid damaging the gas-control valve.

Water, cool to warm

The heater should be installed downstream of the pump and filter and ahead of any automatic sanitizing equipment. That is, the water should be free of particulates or dirt when it enters the heater, and contact with corrosive chemicals should be kept to a minimum by their downstream placement.

It also should be installed as close to the pool or spa in the plumbing run as possible to prevent unnecessary heat loss.

The heater is best located level with the surface of the pool — or as close to level as possible — because manufacturers pre-set their pressure switches for heater installations that are typically 3 feet above or below the pool’s surface. Consult the manufacturer for specific recommendations for elevated or subsurface installations. Once again, sizing is critical: Manufacturers provide specific pipe-sizing recommendations or pipe-sizing charts based on flow rates and distance of run.

One key consideration: When using PVC piping, position a heat sink between the heater and the piping — typically a metal pipe approximately 2- to 4 feet long. For best performance of the resulting PVC/metal connections, use a metal male fitting and a PVC female fitting. Where allowed by codes and manufacturer’s instructions, CPVC — a high-temperature version of PVC — can be connected directly to the heater. To compensate for pipe expansion, a flexible sealant should be used on all piping connections.

Note: Some heaters now are designed to allow for direct PVC connections.

(Video) NATURAL GAS CONNECTED TO RAYPAK SWIMMING POOL HEATER

To avoid damage to plastic filter elements that might be caused by back-siphoning of hot water into the filter, a check valve should be placed in the line between the filter and heater. Likewise, to prevent water with high concentrations of chemicals from backing up into the heater and possibly corroding the heat exchanger, there should be a special chemical-resistant check valve between an in-line chemical feeder and the heater.

The installation may or may not require use of an external bypass valve and a pressure-relief valve: Be sure to check the installation manual for each model’s requirements and other conditions that may require such control devices.

WIRED FOR HEAT

Millivolt (or continuous pilot) systems do not require electrical service to the heater. To enhance energy conservation, however, some areas have required heaters to use intermittent-ignition systems, which do require electrical hookups or line voltage.

For most applications, a qualified, licensed electrician must perform or evaluate this part of the job — from the circuit breaker panel to the heater, or from the load side of the time clock to the heater.

Most heater models accommodate either 120-volt or 240-volt power. The National Fuel Gas Code requires 14-gauge copper wire for electrical service to gas heaters. Electrical wiring should be run in a waterproof conduit and hard-wired into the unit.

If the circulation system is run with a timer, older heaters should be equipped with a low-voltage switch that deactivates the heater before the pump is turned off. This circuit is known as the heater’s fireman switch.

On a millivolt heater, the length of wire between the heater and the timer should not exceed 30 feet. Resistance on longer runs will reduce the millivoltage to a level that will not support reliable operation of the gas valve.

Finally, all such high-voltage circuits require grounding and bonding in accordance with the National Electric Code.

(Video) SWIMMING POOL HEATER NATURAL GAS LINE INSTALLATION

PSN thanks Raypak Inc. for their assistance with this article.

FAQs

Where should a pool heater be placed? ›

Install the heater as close to the filter as possible and approximately 25 feet away from the swimming pool. Installing the unit any farther may cause heat loss since tubing is underground. An "ideal" installation will have about 24" of clearance around the unit with no obstructions above.

Does pool heater go before or after pump? ›

Ideally the water should flow through the heat pump first and then the electric heater second.

How do you hook up a heater for a pool? ›

How To Connect A Pool Heater - YouTube

How do you vent a gas pool heater? ›

How To - Create your own Hayward Pool Gas Heater Vent - YouTube

How far away from house does gas pool heater need to be? ›

This heater must be installed at least five feet from the wall of an above-ground pool. The heater shall not be installed with the top of the vent assembly within 10 feet below or to either side of any opening into the building.

Can you put a gas pool heater under a deck? ›

Do not install a gas pool heater under a deck. You must vent the heater if it's being installed in a pool house. Install the heater within 15' of equipment for optimal heating.

Should I leave my gas pool heater on all the time? ›

No, you shouldn't leave your pool heater running all the time. Not only will it increase your electricity bill, but it will put unnecessary stress on your pool heater. Instead, you should run your pool heater to cycle when necessary during the day. That way, your pool will be warm throughout the day and night.

Should you run pool heater overnight? ›

Not only will it be tough to keep the heat in your pool on colder nights but you will also spend a fortune trying to heat your swimming pool. So unless you have money to burn, it's best not to run your heater at night on an uncovered swimming pool.

Should I turn my pool heat pump off at night? ›

Should I run my heat pump during the day or at night? - YouTube

How long does it take to install a gas pool heater? ›

All in all, pool heater installation can take a single day or it can take a few days—it is entirely contingent on your individual needs. After your pool heater is installed, you'll still likely have to wait a few days before you can use it although, again, this depends on the size of the pool.

Can I install a pool heater myself? ›

Indeed, most pool owners hire a professional to replace their pool heater. Many states require gas appliances to be installed by a licensed contractor; but buying it, placing it and plumbing it – you can do yourself.

What size breaker do I need for a pool heater? ›

Gas pool heaters will also typically have conduit from the time clock, to carry power into the heater, whereas pool heat pumps will require a dedicated breaker, of substantial amperage, usually 30-50 amps.

How far does a pool heater have to be from a fence? ›

A minimum distance of 1.5 m between any equipment or accessory and any lot line must be respected. * A lot fronting on 2 parallel streets. Conditions • The gas tank must be surrounded by a high or low wall, or a fence with a minimum height of 1.5 m, so that it is not visible from the street.

What size gas line do I need for pool heater? ›

In estimation, the heater with a capacity of 200 gallons should use a gas line with a 1" diameter and 1-50 foot distance. While the gas line should be 1.25" diameter for 51–200 feet of distance. If the pool heater has a capacity of 400 gallons, you need a gas line of 1.25" diameter for a distance of 1–50 feet.

Does a pool heater need to be enclosed? ›

You do not have to enclose your pool equipment (pump, filter, heater). A lot of people camouflage it with landscaping or a small fence, so that is not visible. Pool equipment is designed to be outdoors. As long it is taken care and properly maintained of there should be nothing to worry about.

How far does a pool heater have to be from a fence? ›

A minimum distance of 1.5 m between any equipment or accessory and any lot line must be respected. * A lot fronting on 2 parallel streets. Conditions • The gas tank must be surrounded by a high or low wall, or a fence with a minimum height of 1.5 m, so that it is not visible from the street.

How close can a heat pump be to the pool? ›

The Results

Allow a minimum of 12 inches of clearance between the sides of your heat pump and all walls and objects. To be safe, we at AquaCal recommend allowing 24 inches of clearance. Allow five feet of clearance between the top of your heat pump and all roof overhangs, tree branches, and other objects.

Can pool heaters be inside? ›

Generally no. Heat Pumps work by transferring heat from the surrounding air to the pool water. If a heat pump is installed indoors there must be a continuous supply of warm air from which the heat pump can extract heat.

Does a pool heat pump need to be in the sun? ›

Absolutely ! It is almost compulsory to use a solar cover when using a heat pump to heat your pool. Not using a solar cover is like not insulating the loft in your house. As your heat pump puts heat into the pool, it will be lost into the air when a solar cover is not used.

Videos

1. 200k BTU RayPak pool heater installation
(Angel Latimer)
2. Installing a Raypak gas heater on Intex above ground pool the easy way
(3 Days Away)
3. Pool Heater Installed Wrong Causing Rust & Failure - Pool Equipment Installation Tips
(Swimming Pool Steve)
4. Operating a Hayward Gas Or Propane Pool Heater
(Landscrapers LLC)
5. Jandy Heater Installlation complete
(Steve The Pool Guy)
6. Pentair Mastertemp Heater Installation complete
(Steve The Pool Guy)
Top Articles
Latest Posts
Article information

Author: Terence Hammes MD

Last Updated: 01/18/2023

Views: 5703

Rating: 4.9 / 5 (69 voted)

Reviews: 92% of readers found this page helpful

Author information

Name: Terence Hammes MD

Birthday: 1992-04-11

Address: Suite 408 9446 Mercy Mews, West Roxie, CT 04904

Phone: +50312511349175

Job: Product Consulting Liaison

Hobby: Jogging, Motor sports, Nordic skating, Jigsaw puzzles, Bird watching, Nordic skating, Sculpting

Introduction: My name is Terence Hammes MD, I am a inexpensive, energetic, jolly, faithful, cheerful, proud, rich person who loves writing and wants to share my knowledge and understanding with you.